Seitenansicht 5
6
To attach the optional weight pockets system please refer to page 12.
!
WARNING
The Removable Pocket and pouch must be secured with the quick release buckle fully and correctly engaged.
The loss of the pocket during diving may causes positive buoyancy and an uncontrolled ascent that could result
in serious injury or death.
7. VALVE SET UP
SCUBAPRO X-TEK BC´s are completed by the BPI System(Balance Power In ator). The power in ator, when connected
to the tank and regulator by a low pressure hose, makes it possible to control buoyancy in the water (in ation/ de ation of
the BC) by using in ate and de ate buttons.
Connecting the Power In ator The Power In ation Valve allows you to in ate your BC using air from your SCUBA cylinder.
Its LP hose, threaded on a LP port of the  rst stage regulator, is connected to the Power In ation Valve by the Quick
Disconnect Coupling.
To attach the Quick Disconnect Coupling:
1 Make sure that both  ttings are free of contamination prior to connecting them together.
2 Pull back the collar of the Quick Disconnect Coupling while pushing the hose  rmly onto the  tting plug found on the
power in ation valve.
3 Release the collar when the coupling is fully seated on the plug. Pull gently but  rmly on the hose to check for a secure
connection.
4 To disconnect, pull the Quick Disconnect Coupling collar back and disengage the LP hose from the plug.
!
WARNING
Keep water out of the in atable aircell of the BC. Repeated use of the oral valve or the Overpressure Valve
may allow water inside the BC, reducing the amount of buoyancy provided by the BC. This could result in
injury or death. Drain all water out of the BC prior to every use.
8. OPERATION
In ating the BC with the Power In ation Valve
To in ate the BC, press the Power In ation Valve Button. Air should enter the BC. For better control during in ation use
short bursts of air by repeatedly pressing and releasing the power in ator button.
In ating the BC with the Oral Valve
The Oral Valve is found on the end of the airway. It allows you to in ate your BC with your exhaled breath.
Use of this valve for in ation is recommended on the surface or on land prior to diving. It may be used when you cannot,
or do not wish to add air to the BC with the Power In ation Valve.
1 First exhale a small amount of air into the mouthpiece of the valve to purge any water that may be trapped there.
2 With the same breath, continue to exhale while deeply depressing the Oral In ation Valve Button.
3 Release the Oral Valve Button when you inhale fresh air.
4 Repeat steps 2 and 3 until the desired amount of buoyancy is reached.
De ating the BC
!
WARNING
Keep sand and other contamination out of the Oral Valve mouthpiece and valve button. Under certain
conditions, contamination can cause the valve to not close completely. If this occurs while diving, shake the
valve while depressing it several times. If the valve leaks or remains inoperable, terminate the dive. Diving
with a leaking Buoyancy Compensator or with valves that do not operate properly may result in a loss of
buoyancy control that could result in injury or death.
De ating the BC with the Oral Valve (BPI)
Assume a head up position in the water. Raise the Oral Valve above and in front of your face. (This insures the Oral valve will
be positioned above the air bubble in the BC). Depress the Oral Valve button and visually con rm that air is escaping from
the In ator. For best control, let air out in a series of short, measured amounts while observing the effects on your buoyancy.
9865 - Scubapro Manuale X-TEK SIDEMOUNT - totale.indb 6 10/12/2013 10:23:07